Greensboro, North Carolina

Precision cooling.
Practical support.

Technical Methods Co. supplies and supports CANATAL precision-cooling systems for data centers and mission-critical facilities across the United States.

CANATAL precision CRAC unit
FULL LIFECYCLE CAPABILITY Specify · Start · Service
Precision cooling specialists Mission-critical focus Full CANATAL servicing
CANATAL SYSTEMS

Cooling platforms for every density.

From conventional computer rooms to high-density AI infrastructure, CANATAL solutions are configured around the actual thermal load, airflow path and redundancy requirement.

01

Precision CRAC Systems

Floor-mounted DX, chilled-water and dual-cooling configurations for reliable temperature and humidity control in mission-critical rooms.

  • Upflow / downflow
  • DX / CHW / dual cooling
  • EC fan technology
02

In-Row Cooling

Close-coupled cooling positioned at the rack row to control high-density heat loads with short, efficient airflow paths.

  • Hot-aisle control
  • Modular capacity
  • Rack-level precision
03

Fan-Wall Systems

High-air-volume, low-velocity cooling platforms designed for large data halls, serviceability and fan redundancy.

  • N+1 fan arrays
  • Low pressure drop
  • Large data halls
04

Liquid Cooling & CDU

Coolant distribution units and liquid-cooling support for high-performance computing and next-generation density requirements.

  • CDU packages
  • HPC readiness
  • Heat-exchanger control
05

Heat Rejection

Matched air-cooled condensers and heat-rejection equipment engineered as part of the complete precision-cooling system.

  • Matched condensers
  • Low-ambient options
  • Coordinated controls
06

Specialized Systems

Application-specific cooling solutions for telecom, controls, laboratories, imaging suites and other technical environments.

  • Application engineered
  • Flexible configurations
  • Critical environments
COMPLETE SUPPORT

One service partner from selection through operation.

Technical Methods Co. supports the complete CANATAL equipment lifecycle—not simply the equipment sale.

Request service support

Application & selection

Load review, airflow strategy, equipment sizing, redundancy planning and unit selection.

Submittals & coordination

Technical schedules, drawings, electrical data, controls review and project coordination.

Installation support

Site readiness review, contractor coordination and installation guidance for CANATAL equipment.

Startup & commissioning

Pre-start inspection, functional checks, controller setup, performance verification and handover.

Preventive maintenance

Planned inspections, filter and coil care, electrical checks, alarms, controls and operating review.

Diagnostics & repair

Troubleshooting, controls support, component replacement, performance restoration and service reporting.

Parts & lifecycle support

Replacement parts, upgrade guidance and lifecycle planning for dependable long-term operation.

Urgent service response

Priority support for cooling alarms, loss of capacity and mission-critical service requirements.

HOW WE WORK

Engineering clarity at every step.

01

Understand the duty

We review load, design conditions, room layout, power, airflow, controls and redundancy.

02

Configure the system

We coordinate indoor units, heat rejection, options, electrical requirements and project documentation.

03

Support deployment

We assist installation, startup, commissioning and operator handover.

04

Protect performance

We provide maintenance, diagnostics, repairs, parts and lifecycle support.

TALK TO A SPECIALIST

Bring us your cooling requirement.

For equipment selection, quotations, project coordination or CANATAL service, contact Technical Methods Co.